← All vendors

Tier 1 · Full-solution provider · Germany

Siemens

The largest industrial automation company in the world and the default supplier across Europe, Asia, and the Middle East. A single Siemens decision can span field to historian — which means one family's time architecture defines your whole audit scope.

  • PLC · SIMATIC S7 family
  • SCADA · WinCC
  • DCS · PCS 7 / PCS neo
  • Engineering · TIA Portal
S1

Controller families

SIMATIC S7-1500
The current high-end modular line — the standard for mid-to-large manufacturing. Siemens publishes a S7-1500 Y2038 firmware bulletin; our audits treat that as the model case: a bulletin describes the latest release, not the revision running on your floor. We verify per CPU.
SIMATIC S7-1200
Compact entry line for small-to-mid applications. Same discipline as the 1500: confirm firmware generation and the time data types compiled in the TIA Portal project, not the datasheet.
S7-300 & S7-400
The legacy mid- and high-performance estate — still widely deployed, officially on a phase-out path to the 1500. This is where Siemens Y2038 risk concentrates: no bulletin exists for a discontinued line. The decision is epoch-shift arithmetic inside the application, external time handling, or replacement on a schedule you control.
ET 200SP
Distributed I/O and IP20-rated controllers. Small clocks, but they are clocks: device timestamps ride the same PROFINET sync path as everything else.
S7-1500 Software Controller
A PLC as a PC process, for virtualized environments. The time base becomes the host OS plus hypervisor — which is good news (a 64-bit Windows or Linux host supports time64) only if you audit both layers. A guest that trusts a drifting virtual clock inherits the drift.
S2

SCADA, HMI & DCS

SIMATIC WinCC
The SCADA span runs from WinCC Basic on panel HMIs through WinCC Professional to WinCC OA for massive distributed installations. Each edition carries its own time and historian path — the audit records which one your site actually runs, and tests the historian write-through post-2038.
PCS 7 / PCS neo
The DCS for process industries — chemicals, pharma, power. Published Y2038 patches exist for current PCS 7 versions; legacy versions remain 32-bit. PCS neo, the web-based successor, is modern by design but its browser-side and server-side time handling still gets validated like everything else.
ET 200eco & SIRIUS
Rugged compact I/O blocks and the industrial-controls range. No clocks worth worrying about until a timestamp is attached locally — at which point they're on the register like everything else.
SIMATIC Safety
F-CPUs and failsafe modules. Safety functions carry the same time_t consequences as standard logic — and the IEC 61508 validation burden of proving it, twice.
S3

Engineering & languages

TIA Portal — Totally Integrated Automation — is one engineering environment across PLCs, HMI, drives, and safety. That is a gift for an auditor: the project archive exposes the time data types and the calendar arithmetic in one place. We harvest it per site.

The languages tell the age story. Ladder, FBD, SCL (Structured Text), and GRAPH (SFC) on modern platforms read time through IEC 61131-3 types with sensible conversions. STL — Instruction List — is marked legacy for a reason: hand-rolled time arithmetic written before the era of published Y2038 guidance lives there, and it is the first code we read at 2038.

Field note On a Siemens audit we deliver three columns: CPU firmware revisions per panel, TIA Portal time types per application, and PROFINET device clock quality per segment. A plant that scores clean on all three is ready regardless of what the catalog says about its equipment generation.

Siemens estate, audited before 2037.

From S7-400 retrofit planning to WinCC historian validation — we run the register and the time-warp test in the same engagement.